House Summary

Owners: Steve Brown
House Type: 1960 Detached Bungalow
Carbon Saving: 75%
Installed Measures:
  • Cavity Wall Insulation
  • Condensing Boiler
  • Draught-proofing – 0.91 ACH (0.74 m3/h/m2)
  • External Wall Insulation (U-old=0.17W/m2K; new 0.12)
  • Floor Insulation (U=0.12W/m2K)
  • Loft Insulation (U=0.13W/m2K)
  • Low Energy Appliances
  • Low Energy Lighting
  • Solar Hot Water Thermal Panels
  • Triple Glazed Windows (U=0.85W/m2K)
  • Whole house Mechanical Ventilation Heat Recovery
  • PV Solar installed 2018
  • Space heating demand (theory) – 22kWh/m2/year
  • Heat load (theory) – 13W/m2
  • 2 x 1559W radiators for whole house
  • Personal Story:

    Having living in London for many years (Gemma all her life) and in a draughty Victorian house, we wanted to build a low energy house and also move out of London.
    We had made some low level attempts to improve the London house – reducing draughts round windows and floors but the pull to move out tempered the ambition because the cost was too high for a short term benefit.

    Initially we were looking to carry out a self build but, after lengthy searches for land, decided that a bungalow would be the best option to achieve the dream.
    We chose Norfolk for a number of reasons – the sea, relatively close to London as we have friends and family there still, food, good access to outdoor activities like walking and running.

  • Property:

    1960 Detached Bungalow (115m2 incl extension~10m x 11m)
    2016 extension (35m2)

     

  • Measures:
    • New – Triple glazed – U=0.83 Green Building Store Performance range windows
    • New installed draught-proofing
    • Cavity filled walls
    • External wall insulation – 140mm EPC U=0.12
    • 270mm sheep’s wool – U=0.13 loft insulation
    • Floor dug out and 200mm Jabfloor laid down with concrete slab over the top. U=0.13
    • Whole house MVHR installed. Airflow (Vallox) 96SE with summer bypass                               PHPP calcs carried out:- 13W/m2
      – 22 kWh/(m3a)Actual air tightness measured as:
      – ACH = 0.91
      – Permeability @ 50Pa = 0.737 m3/h/m2″
    • Lowest power (9kW and will operate down to 3kW) condensing boiler installed–  Worcester Bosch Greenstar 9i system boiler
    • 2 x 1.5kW radiators in living room and dining room. 1 x 365W dual fuel towel rail in bathroom
    • W-B Greenstore 250 litre TC (Twin Coil) Indirect Unvented Hot Water Cylinder
    • All chimneys removed
    • Worcester Bosch Solar-Lifestyle (about 4.4 to 5.0 m2) solar thermal
    • Mainly LED lighting throughout
    • Fridge / Freezer, TV, Washing Machine – A rated
    • Planned 1380 litre rain water reservoir for gardening use only
    Benefits:

    One of the best side benefits is air quality within the house. The lack of draughts and MVHR means the air is always changed and filtered and make for a very pleasant living environment.

    Favourite Feature:

    Solar hot water – Boiler is switched off from March to October every year!